MOVIN TRACIN Stage · Running a show
Stage 3 · Live
On this page
If the sensors and saved setup have not changed since the last show, use the show checklist.
After setup, a show takes four steps: open Settings, GO LIVE, monitor, and END LIVE.
Preview, then go live
Entering Settings starts the preview automatically. After a Stop pipeline, select Start pipeline at the top right instead. The sensors stream, but nothing is broadcast yet.
Give it 5–15 seconds to warm up. Starting the pipeline locks Calibration — its entry in the stage navigation collapses to N sensors · calibrated.
Select GO LIVE in the top bar. A readiness list appears. If it says NOT READY, complete the step it names; when it says READY, select Go live in the panel. Output starts right away and the workspace switches to Live.

Complete the listed requirements before selecting Go live.
First output check
For a first show, have one person enter the motion capture zone and walk, turn,
and raise an arm. Setup is complete when /MOVIN/PointCloud keeps arriving in
your receiving software and, for a tracked person, /VMC/Ext/Root/Pos and
/VMC/Ext/Bone/Pos arrive too. If you have built a 3D view, compare its
position, scale, direction, and motion against the performer. If messages arrive
but the view is wrong, check the receiving integration against
OSC message format before recalibrating sensors.
The Live stage
The Live stage is a monitoring screen for the running show. While on air, the stage navigation on the left collapses to the stage numbers.

The Live stage while broadcasting.
The top bar shows LIVE and the elapsed time. The viewport stays a live visual reference. The right panel reads from top to bottom:
- OSC output — where the output is going (Sending to). Source can be changed here and applies immediately. The target and port are set back in Settings.
- People — how many people are tracked right now, and the maximum tracked.
- Sensors — how many sensors are sending, with a status indicator for each. A sensor that stops sending shows ✕; a tilted sensor turns orange with ⚠.
- Recording — capture the show to a file. See Recording for diagnosis.
- END LIVE — at the bottom of the panel; the same as END LIVE in the top bar.
If a sensor drops out or tilts mid-show
The show keeps running on the remaining sensors. For what the alert means and what to check, see A LiDAR offline alert appears during a show and A sensor is flagged as tilted.
What you can change while live
Return to Settings at any time. What happens depends on the setting:
| Setting | When it applies |
|---|---|
| Capture zones | Immediately for Zone and Human; All remains the full fused cloud |
| Background removal | Immediately for Human and motion capture (learning needs the pipeline running); no effect on All or Zone |
| Point cloud voxelization | Immediately |
| Motion smoothing | Immediately, in your receiving software — the viewport keeps showing the raw tracking |
| Source (All / Zone / Human) | Immediately — the full fused cloud / the cyan zone / the amber zone with the background removed |
| World orientation | On Apply — immediately, no restart. The zones turn with the stage; the background must be learned again |
| OSC Target IP or Target port | Not while live — the fields are locked. END LIVE, change the target, then GO LIVE again |
| Max tracked people | On the next Restart — processing and output briefly stop, then resume |
| Tracking engine | On the next Restart — processing and output briefly stop while the engine reloads |
| Calibration | Not while live. Select Calibration → Calibrate sensors and confirm Stop & edit calibration |
Recording for diagnosis
If something looks wrong, record it so MOVIN support can reproduce and diagnose it.
- In the Live stage, select Recording → Record.
- Let it run while the problem is visible. The Rec indicator in the top bar shows a running clock.
- Select Stop. The file is saved on the server in the
recordings/mcapfolder; MOVIN support can retrieve it from there.
A recording is an MCAP (.mcap) file with the raw point-cloud data from each
sensor.
A recording still contains movement and spatial data. Handle and share it according to your organization's privacy and data-retention policies.
Ending the show
Select END LIVE in the top bar and confirm.
OSC output stops immediately and you return to Settings. Tracking and the point cloud keep running, so GO LIVE puts you back on air right away.
After the show, select Pipeline → Stop pipeline in the top bar. Sensor input, tracking, and OSC output all stop. It does not turn off the server.
Shut down and pack away
- If recording, select Recording → Stop to finish saving.
- Confirm END LIVE, then select Pipeline → Stop pipeline.
- Open ⋯ → Server controls… → Shutdown, then confirm Shut down in the dialog.
- Wait until the server has fully powered off. A blank screen alone does not confirm it.
- Once shutdown completes, turn off the PoE switch and monitor, then disconnect cables for packing.
Use the server's physical power button to start it next time. Recalibrate after moving or packing away the sensors.