Find the symptom, try the action, and if it does not help, contact MOVIN support. During a show, Restart briefly interrupts processing and output.

The workspace does not open

  • No signal — check monitor power, the selected input, and the display cable (HDMI or DisplayPort).
  • Desktop only (the workspace window was closed) — double-click the MOVIN TRACIN Stage icon on the desktop. If it does not open, open a browser on the server and enter http://localhost:8000. If that fails too, reboot the server.
  • An error is shown — report the text to MOVIN support.

A sensor is missing or shows Disconnected

Check its power and network cable, then select Reconnect under Connect sensors.

A sensor shows Standby or No data

It is connected but not streaming. In Calibration Step 1 (Setup), select Sensor stream → Try again. Otherwise open Settings to start the pipeline, or Restart if it is already running.

PTP sync never turns green

Contact MOVIN support.

The view stays empty

It is normal for the view to stay empty for 5–15 seconds after starting. After that, check the Sensors indicator and the viewport Display selection, then Restart.

The 3D scene looks flat

Contact MOVIN support.

The scene is misaligned (doubled walls)

A sensor has moved or the saved calibration no longer fits. Stop the pipeline and recalibrate.

Calibration cannot be opened

It is locked while the pipeline runs. Select Calibrate sensors and confirm Stop & edit calibration, or select Pipeline → Stop pipeline. If you were live, output stops; select GO LIVE again to resume.

Settings is locked or Start pipeline is disabled after a sensor change

A connected LiDAR is not calibrated — the stage navigation reads LiDAR N not calibrated — Recalibrate. Recalibrate with every connected sensor, or disconnect the new one.

If the stage navigation reads Sensor set changed — press Reconnect instead, a LiDAR was unplugged or added after Connect. Open Connect sensors and select Reconnect. If the connected set no longer matches the saved calibration, recalibrate.

Calibration Confirm is disabled

In Step 2 (First calibration), keep collecting until every sensor is ready. In Step 5 (World alignment), wait a few seconds after World solve completes.

An error warning appears after refining

The warning reads, for example, Average error … mm — over the 100 mm target. Select Capture more and collect, then select Stop capture and Refine again. If the warning persists, contact MOVIN support.

Background learning does not complete

The pipeline must be running and the stage empty. Turn Remove background off and on, then choose Learn a new one.

A person at the stage edge is not tracked

Check the capture-zone bounds, blocked sensor views, and Max tracked people.

A LiDAR offline alert appears during a show

One sensor stopped sending, for example LiDAR 204 offline — running on 3 of 4, reduced coverage. The show continues on the rest, with less coverage where that sensor was looking, and Sensors in the top bar shows 3/4.

Check its power and network cable. If it cannot be brought back now, select Acknowledge on the alert. The warning stays quiet for the rest of the run; the sensor list and the count keep showing it.

A sensor is flagged as tilted

If a stand is bumped or a clamp slips, a line such as 202 has tilted 24.2° — check it. You may need to recalibrate. appears under Sensors in the Live panel, and that sensor's status indicator and Sensors in the top bar turn orange. 202 is not where it was calibrated means it no longer matches the saved calibration.

Check its stand and clamp. If it has moved, recalibrate after the show.

The receiving software gets no data

  1. Check Target IP and Target port under OSC output. A value saves when you leave the field. While LIVE the fields are locked — select END LIVE to change them.
  2. Select Test connection. If the computer answers but /movin/test does not appear, check the receiving port, UDP input, address filter, and firewall.
  3. If the test arrives but show data does not, check that you are LIVE and that the selected Source contains points.

A "Backend unreachable" banner appears

The control service is not responding. Wait a moment; if it persists, contact MOVIN support.

What to include in a support request

Use the MOVIN contact provided with your delivery or installation, and send:

  • The installation location and when the problem began
  • A screenshot showing the top status and Sensors, plus any error text
  • What changed since the last successful run (sensors, set, settings)
  • For reception issues: the receiving software, Target IP and Target port, and whether /movin/test arrives
  • A diagnostic recording if useful